A rapid LC-MS/MS method for the determination of marbofloxacin in plasma and synovial fluid is presented in this study. The method uses a rapid sample preparation which only requires an ultrafiltration step with centrifugal filter devices. The optimized procedure allows a minimal need of sample (175μL), particularly useful for synovial fluid samples which amount is rather limited; it is simple, rapid and easily applicable providing anyhow a satisfactory clean up, demonstrated by post-infusion experiments. On the other hand to maximize the speed of the analysis an ultrafast chromatographic separation has been obtained by selecting a column of 20mm; the reduced run-time is suitable for processing numerous samples on a daily basis. Linearity was assessed in the range 5-2500ngmL(-1); ofloxacin was used as internal standard. LOD and LOQ were respectively 1 and 5ng/mL. The method was successfully applied to a set of samples generated during an experimental veterinary study.

Determination of marbofloxacin in plasma and synovial fluid by ultrafiltration followed by HPLC-MS/MS

SERGI, Manuel;COMPAGNONE, DARIO;CELANI, GIANLUCA;VARASANO, Vincenzo;PETRIZZI, Lucio;AMORENA, Michele
2016-01-01

Abstract

A rapid LC-MS/MS method for the determination of marbofloxacin in plasma and synovial fluid is presented in this study. The method uses a rapid sample preparation which only requires an ultrafiltration step with centrifugal filter devices. The optimized procedure allows a minimal need of sample (175μL), particularly useful for synovial fluid samples which amount is rather limited; it is simple, rapid and easily applicable providing anyhow a satisfactory clean up, demonstrated by post-infusion experiments. On the other hand to maximize the speed of the analysis an ultrafast chromatographic separation has been obtained by selecting a column of 20mm; the reduced run-time is suitable for processing numerous samples on a daily basis. Linearity was assessed in the range 5-2500ngmL(-1); ofloxacin was used as internal standard. LOD and LOQ were respectively 1 and 5ng/mL. The method was successfully applied to a set of samples generated during an experimental veterinary study.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11575/91348
Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 13
  • ???jsp.display-item.citation.isi??? 11
social impact