The aim of this retrospective study was to evaluate the clinical and radiographic outcomes of 21 cats that underwent coxofemoral toggle stabilization using the Mini TightRope (R) Fixation System (mTR (R)). Data were compiled from client-owned cats with traumatic hip luxation. Each cat underwent the same protocol including orthopedic assessment, preoperative radiographic evaluation, surgical procedure, postoperative management and clinical re-examination at 14 days, 8 weeks and 12 months following surgery. Age, body weight, implants and osteoarthritis progression were recorded. A lameness score 0-4 was assigned to each cat. Pain upon hip extension was not quantified but as pain reaction or no pain reaction. Major complications and osteoarthritic (OA) changes were recorded. Osteoarthritic changes were classified on a 0-4 scale. Twenty-one cats were included in the study. Coxofemoral luxations were stabilized using a mTR (R). At 8 weeks, weight bearing was considered normal (grade 0) in all cats and no pain reaction was elicited during hip extension. One year after surgery, orthopedic examination was within the normal limits and according to the owners, all animals exhibited a normal physical activity. No complications were recorded. Evidence of slight OA changes were observed in 5 out of 21 cats. The final outcome was considered excellent in 16/21 patients and good in 5/21 cats. The application of the mTR (R) system can be considered a suitable surgical treatment in cats affected by traumatic hip luxation.
TRAUMATIC COXOFEMORAL LUXATION IN CATS TREATED WITH HIP-TOGGLE STABILIZATION USING THE MINI TIGHTROPE® FIXATION SYSTEM|STABILIZACIJA KUKA UZ UPOTREBU MINI TIGHTROPE® FIXATION SISTEMA KOD MAČAKA SA TRAUMATSKOM KOKSOFEMORALNOM LUKSACIJOM
Tamburro R.
Conceptualization
;Pratesi A.Writing – Original Draft Preparation
;Collivignarelli F.Methodology
;Bianchi A.Methodology
;Paolini A.Methodology
;Falerno I.Investigation
;de Bonis A.Investigation
;Vignoli M.Writing – Review & Editing
2022-01-01
Abstract
The aim of this retrospective study was to evaluate the clinical and radiographic outcomes of 21 cats that underwent coxofemoral toggle stabilization using the Mini TightRope (R) Fixation System (mTR (R)). Data were compiled from client-owned cats with traumatic hip luxation. Each cat underwent the same protocol including orthopedic assessment, preoperative radiographic evaluation, surgical procedure, postoperative management and clinical re-examination at 14 days, 8 weeks and 12 months following surgery. Age, body weight, implants and osteoarthritis progression were recorded. A lameness score 0-4 was assigned to each cat. Pain upon hip extension was not quantified but as pain reaction or no pain reaction. Major complications and osteoarthritic (OA) changes were recorded. Osteoarthritic changes were classified on a 0-4 scale. Twenty-one cats were included in the study. Coxofemoral luxations were stabilized using a mTR (R). At 8 weeks, weight bearing was considered normal (grade 0) in all cats and no pain reaction was elicited during hip extension. One year after surgery, orthopedic examination was within the normal limits and according to the owners, all animals exhibited a normal physical activity. No complications were recorded. Evidence of slight OA changes were observed in 5 out of 21 cats. The final outcome was considered excellent in 16/21 patients and good in 5/21 cats. The application of the mTR (R) system can be considered a suitable surgical treatment in cats affected by traumatic hip luxation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.