(1) Two-dimensional shear wave elastography (2D-SWE) employs an ultrasound impulse to produce transversely oriented shear waves, which travel through the surrounding tissue according to the stiffness of the tissue itself. The study aimed to assess the reliability of 2D-SWE for evaluating the elastosonographic appearance of the distal attachment of the fetlock joint capsule (DJC) in sound horses and in horses with osteoarthritis (OA) (2). According to a thorough evaluation of metacarpophalangeal joint (MCPJ), adult horses were divided in a sound Group (H) and in OA Group (P). Thereafter, a 2D-SWE of MCPJs was performed. Shear wave velocity (m/sec) and Young's modulus (kPa) were calculated independently by two operators at each selected ROI. Statistical analysis was performed with R software. (3) Results: 2D-SWE had good-excellent inter-CC and intra-CC in both groups. Differences in m/s and kPa between Groups H and P were found in transverse scans with lower values in Group P. No correlation with age or DJC thickness was found. (4) Conclusions: 2D-SWE was repeatable and reproducible. In Group H, DJC was statistically stiffer than in Group P only in transverse scan. The technique showed poor sensitivity and specificity in differentiating fetlocks affected by OA.

2D-SWE of the Metacarpophalangeal Joint Capsule in Horses

Guerri, Giulia;Palozzo, Adriana;Straticò, Paola
;
Varasano, Vincenzo;Celani, Gianluca;Di Francesco, Paola;Vignoli, Massimo;Petrizzi, Lucio
2022-01-01

Abstract

(1) Two-dimensional shear wave elastography (2D-SWE) employs an ultrasound impulse to produce transversely oriented shear waves, which travel through the surrounding tissue according to the stiffness of the tissue itself. The study aimed to assess the reliability of 2D-SWE for evaluating the elastosonographic appearance of the distal attachment of the fetlock joint capsule (DJC) in sound horses and in horses with osteoarthritis (OA) (2). According to a thorough evaluation of metacarpophalangeal joint (MCPJ), adult horses were divided in a sound Group (H) and in OA Group (P). Thereafter, a 2D-SWE of MCPJs was performed. Shear wave velocity (m/sec) and Young's modulus (kPa) were calculated independently by two operators at each selected ROI. Statistical analysis was performed with R software. (3) Results: 2D-SWE had good-excellent inter-CC and intra-CC in both groups. Differences in m/s and kPa between Groups H and P were found in transverse scans with lower values in Group P. No correlation with age or DJC thickness was found. (4) Conclusions: 2D-SWE was repeatable and reproducible. In Group H, DJC was statistically stiffer than in Group P only in transverse scan. The technique showed poor sensitivity and specificity in differentiating fetlocks affected by OA.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11575/123519
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact